Bare Wire Diameter: | 0.35mm | Product Name: | Triple Insulated Wire |
---|---|---|---|
Overall Diameter: | 0.55mm | Thermal Class: | 130 |
Color: | Yellow | Conductor Type: | Solid |
High Light: | 0.55mm Triple Insulated Magnet Wire,Winding Triple Insulated Magnet Wire,Rust Resistant Triple Insulated Wire |
Yellow 0.1 - 1.0mm Magnetic Coil Winding Wire Triple Insulated Wire
Triple Insulated wire or TIW is wildely used in transformer, our quanlity is similar with Furukawa, even is better at CLASS F. Self solderable makes soldering process much easier. UL system certificated give you perfect quality.
We have 19 high-speed production lines with a monthly production capacity of 150 million meters, the largest production scale in China; we have our own insulation material formula and intellectual property rights; our triple insulated wire have passed UL, German VDE and China CQ C authority Certified, and obtained UL insulation system; we have a core competitive engineering and technical team, and continue to provide customers with quality products and services.
Features and Benefits:
1. Greatly reduce the size and weight of transformers.
2. Greatly improve the efficiency of transformer by reducing the distance between coil.
3. Allow to wind directly on the top of enameled wires. Eliminate the interleaved insulation tapes, barriers and insulating sleeves.
4. Shock resistance, Corrosion Resistant
5. Excellent durability, Durable Resistant
6. Superior strength, Reliability
7. Rust resistant, Affordability
8. Low maintenance
Transformers
Coils
Switchgear
Solenoid Valves
Automobiles
Electrical Appliance
Industrial Electronics
Pumps & Fans Motor
Specification
NO.
|
Characteristics
|
Test Standard
|
Conclusion
|
1
|
Package
|
Whether Package condition is good(including carton,spool, PE film, Air bubble film).Whether carton's seal is complete
|
OK
|
2
|
Bare Wire Diameter
|
0.50±0.01MM
|
0.347-0.352
|
3
|
Overall Diameter
|
0.55±0.02MM
|
0.547-0.554
|
4
|
Conductor Resistance
|
MAX: 189.9Ω/KM
|
182.8Ω/KM
|
5
|
Breakdown voltage of straight wire
|
The length of wire 305mm,wind on the copper bar, test condition 1mA/60s5.0KV
|
OK
|
6
|
Breakdown voltage of bending wire
|
The length of wire 305mm , Test condition:1mA/60S/4.5KV
|
OK
|
7
|
Breakdown voltage of twist wire
|
The length of wire 125mm , Test condition: 50HZ/1mA/60S/AC10KV
|
OK
|
8
|
Elongation
|
MIN:20%
|
23.8-26.9%
|
9
|
Solder ability
|
420 4-5 Secs
|
OK
|
Conclusion
|